Digital Carbon Monoxide (CO) Gas Sensor Module - DGS-CO 968-034
• Measurement Range: 0 to 1000 ppm
• Resolution: 0.1 ppm
• Zero Accuracy: ± 1 ppm
• Measurement Accuracy: 15% of reading
• Measurement Repeatability: < ± 3% of reading or 2 ppm, whichever is greater
• T90 Response Time (100 ppm step): < 30 seconds (15 seconds typical)
- Quantity:
- - +
Product Specification
DGS-CO 968-034 Digital CO Sensor Module DESCRIPTION
Easily add Carbon Monoxide sensing to your IoT application with our digital CO sensor module that provides a calibrated and temperature compensated output.
0 to 1000 ppm Carbon Monoxide sensor with digital output
DGS-CO 968-034 Digital CO Sensor Module BENEFITS
• Low Power – 1 mW @ 1 minute sampling
• Fast Response – 15 seconds typical
• Calibrated & Temp. Compensated Output
• Simple Digital UART Interface
• Integrated T & RH Sensors
• Robust 10-year Estimated Lifetime
• ROHS Compliant
• Small form Factor
• UART to USB adapter provided
• Lightweight (< 2 oz.)
DGS-CO 968-034 Digital CO Sensor Module APPLICATIONS
• Life Safety Levels
• Air Quality Levels
DGS-CO 968-034 Digital CO Sensor Module MEASUREMENT PERFORMANCE CHARACTERISTICS
Based on Standard Conditions 25 ºC, 50% RH and 1 atm
Measurement Range |
0 to 1000 ppm |
Resolution |
0.1 ppm |
Zero Accuracy |
± 1 ppm |
Measurement Accuracy |
15% of reading |
Measurement Repeatability |
< ± 3% of reading or 2 ppm, whichever is greater |
T90 Response Time (100 ppm step) |
< 30 seconds (15 seconds typical) |
Power Consumption |
1 mW for 1 minute triggered samples 12 mW for continuous sampling 5, 10 30, 60 second intervals |
Expected Operating Life |
> 5 years (10 years @ 25± 10C; 60 ± 30% RH) |
Operating Temperature Range |
-20 to 40 °C (-30 to 55 °C intermittent) |
Operating Humidity Range |
15 to 95% (0 to 100% non-condensing intermittent) |
Mechanical Dimensions |
1.75 x 0.82 x 0.35 in. (44.5 x 20.8 x 8.9 mm) |
Weight |
< 2 Ounces |
DGS-CO 968-034 Digital CO Sensor Module ABSOLUTE MAXIMUM RATINGS
Parameter |
Conditions |
Min. |
Rec. |
Max. |
Units |
Maximum Concentration |
Short term exposure |
0 | 1000 | 5000 |
ppm |
Supply Voltage |
Regulated |
2.6 |
|
3.6 |
V |
Storage Temperature |
Vapor sealed @ 50% RH |
5 | 20 | 30 |
̊C |
Storage Humidity |
Non-condensing, vapor sealed |
20 | 50 | 80 |
% RH |
Storage Pressure |
Vapor sealed |
0.8 |
1 |
1.2 |
atm |
Storage Time |
Vapor sealed |
- |
12 |
- |
Months |
Operating Temperature |
< 10 hours |
-40 |
- |
50 |
̊C |
Operating Humidity |
< 10 hours, Non-Condensing |
0 |
- |
100 |
% RH |
Operating Pressure |
Transient pulses |
-0.5 |
0 |
0.5 |
atm |
Operating Temperature |
Continuous |
-30 |
25 |
50 |
̊C |
Operating Humidity |
Continuous, Non-Condensing |
10 |
50 |
95 |
% RH |
Operating Pressure |
Continuous |
0.8 | 1 | 1.2 |
atm |
ESD Rating |
Human Body Model |
2 |
|
8 |
kV |
DGS-CO 968-034 Digital CO Sensor Module ELECTRICAL CHARACTERISTICS
Parameter |
Conditions |
Min. |
Typ. |
Max. |
Units |
Supply Current |
V+ = 3.0 V |
0.05 |
|
4 |
mA |
Power Consumption |
V+ = 3.0 V |
0.15 |
|
12 |
mW |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)