BasicLine BL 520 Temperature Transmitter
-
Price
Price on request ≥1piece
-
Model Number
BL 520 -
Data Sheet
-
Package
Original packaging -
Specs
BL 520 -
Quantity
- +Send Inquiry
Find Similar Products
-
Thermopile Infrared Temperature Sensor Module
Model Number:TSEV01CL55
MOQ:1
-
Infrared Thermopile Temperature Sensor
Model Number:TS318-1B0814
MOQ:1
-
Assembled Armored Platinum Resistor
Model Number:WZPKK Series
MOQ:1
-
Armored Thermocouple
Model Number:WR Series
MOQ:1
-
“ZERO DRIFT” High Accuracy Integrated Temperature Transmitter
Model Number:WBZPKK-&WXBZPKK- Series
MOQ:1
-
“ZERO DRIFT” High Accuracy Thermocouple Integrated Temperature Transmitter
Model Number:WBR&WXBR Series
MOQ:1
Product Description
1.Caution!
Only trained and qualified personnel should install the BasicLine BL 520 temperature transmitters.
Do not connect the device to power supply before it is professionally installed. Do not change the measuring range during operation.
Be sure to observe the national codes and regulations for installation and selection of cables and lines.
You must install a clearly identifiable two-pole circuit breaker between device and mains supply.
Mains supply must be protected by a fuse ≤ 20 A.
2. Intended Use
The BasicLine BL 520 temperature transmitters provide connection possibilities for most of the common thermocouples and resistance thermometers.
When a resistive sensor is connected, 2-, 3-, or 4-wire configuration is automatically recognized at device startup.
Note: When the configuration is changed from 2-wire to 3-wire (or 4-wire) or from 3-wire to 4-wire, this is only recognized after the device's next restart.
The output signal is adjustable to 0 / 4 ... 20 mA, or 0 … 5 / 10 V.
The calibrated range selection is performed using DIP and rotary encoder switches. The device provides a 24 V DC power supply and galvanic 3-port isolation.
Sensor type | (Standard) | Range [°C] |
Pt100 | (EN 60751) | -200 ... +850 |
Pt1000 | (EN 60751) | -200 ... +850 |
Connection |
|
2-, 3- or 4-wire (automatic identification,LED signaling) |
Resistance range (incl. line resistance) |
|
Temperature measurement: 0 ... 5 kΩ |
Max. line resistance |
|
100 Ω |
Supply current |
|
Max. 500 µA |
Line monitoring |
|
Open circuits |
Input error limits |
|
For resistances < 5 kΩ: |
|
|
± (50 mΩ + 0.05 % meas.val.) |
|
|
for spans > 15 Ω |
Temperature coefficient |
|
0.005 %/K of adjusted end value |
at the input |
|
(average TC in permitted operating |
|
|
temp range, reference temp 23 °C) |
Thermocouple input data |
|
|
Sensor type | (Standard) | Range [°C] |
J | (EN 60584-1) | -210 ... +1200 |
K | (EN 60584-1) | -200 ... +1372 |
Input resistance |
|
> 10 MΩ |
Max. line resistance |
|
1 kΩ |
Line monitoring |
|
Open circuits |
Input error limits |
|
± (10 µV + 0.05 % meas.val.) for spans |
|
|
> 2 mV |
Temperature coefficient |
|
0.005 %/K of adjusted end value |
at the input |
|
(average TC in permitted operating |
|
|
temp range, reference temp 23 °C) |
Ref. junction compensation |
|
Internal or external (Pt 100) |
Error of external |
|
Via Pt100 for Tcomp= 0 ... 80 °C: |
ref. junction compensation |
|
± (80 mΩ + 0.1 % meas.val.) |
Error of internal |
|
± 1.5 °C |
ref. junction compensation |
|
|