• Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
Mouse over image to zoom

Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃

ISweek online 2h ago

ISweek_com

Send Inquiry Chat Now
  • Price

    Price on request   ≥1piece

  • Model Number

    MIDA-MA-70
  • Data Sheet

  • Package

    Original packaging
  • Specs

    MIDA-MA-70
  • Quantity

    - +
  • Send Inquiry

Product Description

Absolute Pressure Microelectronic Transducers MIDA-MA-70 Features:

Pressure range 0~10MPa

Operating temperature range -40℃~+120℃

high accuracy, high stability

wear resistance, impact resistance and anti-corrosion


Absolute Pressure Microelectronic Transducers MIDA-MA-70 Specification

Applications  Industrial instrumentation & process control systems
Measured medium
 Liquids and gases compatible with titanium alloys and stainless steels
Pressure range, MPa  0-0,04…. - 0-10
Accuracy (comb. L.H.R), no more than, ±%
 0,1 (0,2) of output signal variation range
Zero output (at temperature of 20℃), mV/V
 ± 0,2 with accuracy 0,1%; ± 0,3 with accuracy 0,2%;
 ± 0,5 within pressure range 0-0,006
Output range, mV/V  5 ± 0,2 with accuracy of 0,1%;
 5 ± 0,3 with accuracy of 0,2%;
 3± 0,2 within pressure range 0-0,01 MPa
 1,5 ± 0,2 for 0-0,006 MPa range with accuracy 0,1%;
 1,5 ± 0,3 for 0-0,006 MPa range with accuracy 0,2%
Operating temperature range, °С  -40 ...+120
Compensation temperature range, °С
 -40 ...+120
Additional temperature error in
compensated temperature range,
% of zero output, no more than
 2 with accuracy of 0,1%;
 3 with accuracy of 0,2%;
 3 for 0-0,006 MPa range with accuracy of 0,1%;
 4,4 for 0-0,006 MPa range with accuracy of 0,2%
Supply voltage, V  5-15 DC
Overpressure, no more than
 2 Pnom for ranges from 0-0,006 to 0-2,5 MPa;
 1,5 Pnom for ranges from 0-4 to 0-60 MPa;
 1,25 Pnom for ranges from 0-100 to 0-160 MPa
Insulation resistance
 Not less than 100 MOhm at voltage of 500 V DC


Absolute Pressure Microelectronic Transducers MIDA-MA-70 Overall and mounting dimensions